Test Circuit For Testing a Non-Dimmable Lamp at a Dimmer or Electronic Switch
1. Use
Applying non-dimmable self-ballasted lamps on a dimmer or an electronic switch is to be tested as a possible case of abnormal operation..
2. Reference standards
IEC60560-Fig8
4. Technical parameters
Internal dimension | 105 X 267 X220 W *D*H mm |
2 | potentiometer R1 |
3 | resistor R |
4 | Triac BTA16/700 |
5 | Diac DB3 |
6 | capacitor C1 = 100 nF |
7 | capacitor C2 = 68 nF to 150 nF |
8 | induction L1 = 3 mH |
9 | basic load, incandescent lamp P = 60 W |
11 | I r.m.s. Ammeter |
Ammeter input Power | AC 220V 50Hz |
Test procedure:
Determine R1 and S1 setting at which the maximum I r.m.s . occurs.
Test at this situation, and if the lamp passively fails within 60 min, repeat the test at 10 % lower I r.m.s . The lower I r.m.s . shall be set in the decreasing potentiometer resistance direction.