Brand Name :Kingpo
Certification :Calibration Certificate
Place of Origin :China
MOQ :1
Price :To be Quoted
Payment Terms :T/T
Supply Ability :20 sets per month
Delivery Time :35 working days
Packaging Details :safety carton pack or plywood box
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Temperature and Humidity Walk-in Test Chamber / Walk in Cooling Room

Description

Temperature and Humidity Walk-in Test Chamber suitable for the whole machine or large parts of low temperature, high temperature, high and low temperature change, constant time heat, high and low temperature alternating moisture and heat test...

The size and function of the studio can be changed according to user requirements. Pieced box body, beautiful and generous shape; Scientific airway design can meet the needs of different customers. Using touch screen, PLC program controller.

SPECIFICATIONS

SR NO SPECIFICATION KP-WI1500
1 TEMPERATURE RANGE -50C TO +100C
2 HUMIDITY RANGE 40% TO 98% RH
3 DIMENSION (INTERNAL) (W X D X H) 1500 X 1500 X 3000 MM
4 DIMENSION (EXTERNAL) (W X D X H) 2850 X 1700 X 3200 MM
5 RAMP

VARIABLE, TEMP. 0~5C / MIN & HUMIDITY 0~5%/MIN

IN AVERAGE, NO LOAD

6 ACCURACY TEMP. ±1C, HUMIDITY ±2.5%RH
7 INTERIOR WALLS STAINLESS STEEL 304
8 EXTERIOR WALLS COLD ROLLED STELL PLATE WITH BAKING FINISH
9 TEMPERATURE & HUMIDITY MEASUREMENT AND CONTROLLER

32 BIT CONTROL AND MONITORING SYSTEM.

INTERFACE FACILITY WITH RS232

PROGRAMMABLE TEMP. HUMID. CONTROLLER

10 VIEWING WINDOW MULTI PANE GLASS WINDOW SIZE
11 PORT HOLES 50 MM DIAMETER FOR WIRE ROUTING
12 POWER SUPPLY REQUIREMENT THREE PHASE, AC380 V ± 10 %, 50 HZ
13 SOUND PRESSURE LEVEL <72DB (A)
14 CONDENSER COOLING WATER COOLED
GENERAL TECHNICAL SPECIFICATION
15 THERMAL CYCLIC CHAMBER
15.1 CHAMBER WITH INTERNAL AIR CIRCULATION, AND ALL THE HEATERS AND COOLING COIL LOCATED BEHIND/BELOW THE FALSE SHEET OF THE CHAMBER AND OUTSIDE THE WORKING SPACE
16 INTERIOR
16.1 THE CONDITIONING WITH AIR CIRCULATION TO MAINTAIN UNIFORM TEMPERATUR
16.2 INTERIOR HAVE PROVISION FOR ARRANGING STAINLESS STEEL
17 INSULATION
17.1 INSULATION IS ASBESTOS-FREE CSC-FREE, WITH LOW THERMAL CONDUCTIVITY, POLYRTHENE PU FOAM
18 COOLING SYSTEM
18.1

CASCADE TYPE, REFRIGERATION SYSTEM WITH HERMETICALLY SEALED REFRIGERATION

CYCLES WITH ENVIRONMENT AND OZONE FRIENDLY AND CHLORIDE FREE REFRIGERATION

19 DOOR
19.1 LOCKABLE FRONT OPENING, WITH DOUBLE DOOR LATCH EASY TO OPEN
19.2 WITH SILICON GASKET FOR PERFECT SEALING
20 VIEWING WINDOW
20.1 VIEWING INTERLOCK IS SEALED TO AVOID LEAKAGE AND PROVIDED WITH HEATING PROVISION TO PREVENT CONDENSATION
21 ILLUMINATION
21.1 INERNALLIGHT ON VIEWING WINDOWS WITH EXTERNAL CONTROL
22 TEMPERATURE MEASURING AND CONTROL SYSTEM
22.1

THE TEMPERATURE MEASURING AND CONTROL SYSTEM ADOPTS MICROPROCESSOR SYSTEM AND PROVIDED WITH TOUCH PANEL FOR MONITORING AND DIGITAL DISPLAY:

SUPPLIED WITH SUPPORT SOFTWARE

SOFTWARE IS CAPABLE TO VISUALIZE AND GRAPHICAL ANALLYSE THE MEASURED & RECORDED VALUE.

A. GRAPHICAL REPRESENTATION AND DIGITAL DISPLAY AND CONTROL OF SET AND ACTUAL VALUES
B. DIGITAL INPUT AND DISPLAY OF TEMPERATURE IN DEGREE CENTIGRADE
C. FAULT DIAGNOSIS SYSTEM
D. 120 STROAGE OF PROGRAMMES
22.2 HAVE ADJUSTABLE SAFETY CUT-OUT AGAINST HIGH AND LOW TEMPERATURE
22.3 FACILITY TO PROGRAMME TEMPERATURE MEASURING USING SENSOR PT100
23 RECORDER & PC CONNECTIVITY
23.1 STANDARD RS -232 INTERFACE FOR PC CONNECTIVITY
23.2 RS-232 CABLE FOR PC CONNECTIVITY ALONG WITH PC CONNECTIVITY SOFTWARE
24 PORT HOLES
24.1 EACH PORT HOLE PROVIDED WITH SILICON SEALING BUNKER (PLUG)
25 ELECTRICAL PANEL
25.1 ALL POWER CONNECTORS, PROTECTION DEVICES POWER CONTROL LOGIC BUILT IN THE CONTROL PANEL INTEGRATED TO THE CHAMBER
25.2 ALL ELECTRICAL CABLES TAGGED WITH ID NUMBER
25.3 ALL ELECTRICAL FUNCTION CIRCUIT EQUIPPED WITH ITS OWN SAFETY DEVICE THAT SHUTS DOWN THE RELEVANT CIRCUIT OR THE ENTIRE TEST CHAMBER IF A FAULTY DEVELOPS
25.4 ALL ELECTRICAL SYSTEMS COMPLY WITH RECOGNIZED TECHNICAL REGULATION AS WELL AS WITH THE ACCIDENT PREVENTION REGULATIONS.
26 STANDARD PROTECTION
26.1 PROTECTIVE FEATURE TO BE PROVIDED AS FOLLOWS:
A. OVER LOAD TRIP & EARTH LEAKAGE TRIP FOR COMPLETE CHAMBER
B. OVER LOAD TRIP FOR COMPRESSORS, HEATERS AND MOTORS
C. OVER TEMPERATURE CUT-OFF FOR COMPRESSORS
D. HEATER BE CUT OFF, IF AIR CIRCULATION BLOWERS ARE OFF
27 OPERATING SYSTEM
27.1 DETAILED OPERATING & MAINTANANCE MANUAL
A. OPERATIONAL INSTRUCTION
B. COMPLETE LIST PARTS
C. PREVENTIVE MAINTENANCE PROCEDURE
D. TROUBLE SHOOTING MEASURES