KingPo Technology Development Limited

IEC Testing Equipment

Manufacturer from China
Verified Supplier
9 Years
Home / Products / Lamp Cap Gauge /

Gauge For Testing Protection Against Bulb-Neck Damage And For Testing Contact-Making In Lampholders E27-7006-22a-5

Contact Now
KingPo Technology Development Limited
Visit Website
City:hong kong
Province/State:hong kong
Country/Region:china
Contact Person:MsLynette Wong
Contact Now

Gauge For Testing Protection Against Bulb-Neck Damage And For Testing Contact-Making In Lampholders E27-7006-22a-5

Ask Latest Price
Video Channel
Brand Name :kingpo
Model Number :E27-
Certification :iso9001
Place of Origin :china dongguan
MOQ :1
Price :To be quoted
Payment Terms :T/T
Supply Ability :1000 pcs per month
Packaging Details :safety carton pack or plywood box
MATERALO :SUS420
Delivery Time :7 working days
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC60061-3: 7006-22A-5 E27 Gauge for Testing Contact-Making and Protection Against Accidental Contact During Insertion of Lamps in Lampholders

The drawing is intended only to illustrate the dimensions essential for interchangeability.The drawings are intended only to illustrate the essential dimensions of the gauge.The drawings are intended only to illustrate the essential dimensions of the gauge.

(1) Dimension E is the reference diameter associated with dimension S.

PURPOSE: To check E27 lampholders in respect of:

a) Contact-making with lamps having adverse dimensions.

b) Protection against accidental contact with live parts, viz. the cap shell, during insertion of a

lamp.

TESTING: The holder is connected in the test circuit as shown.

a) With switch A in position 2 and switch B open, the gauge is screwed fully home.

In this position, both lamps shall light.

b) After the test of a) above, the gauge is withdrawn until the lamps are extinguished.

Switch A is moved to position 1 and switch B is closed. The gauge is then screwed in slowly until

either of the lamps lights. With the gauge held in this position, switch B is opened and the test

probe at the side of the gage is slid downwards as far as it will go into the space between the gauge

and the holder. In this position the lamps shall not light.