KingPo Technology Development Limited

Manufacturer from China
Verified Supplier
9 Years
Home / Products / Flame Test Equipment /

A2L Refrigerant Flame-Retardant Enclosure Test Machine Compliant with IEC 60335-2-40:2022 and GB/T 4706.32-2024 Featuring Adjustable 0.5-10mm Electrode Spark Gap

Contact Now
KingPo Technology Development Limited
Visit Website
City:hong kong
Province/State:hong kong
Country/Region:china
Contact Person:MsLynette Wong
Contact Now

A2L Refrigerant Flame-Retardant Enclosure Test Machine Compliant with IEC 60335-2-40:2022 and GB/T 4706.32-2024 Featuring Adjustable 0.5-10mm Electrode Spark Gap

Ask Latest Price
Video Channel
Brand Name :Kingpo
Model Number :KP-FT3541
Certification :ISO 17025
Place of Origin :China
MOQ :1
Price :To be quoted
Payment Terms :T/T
Packaging Details :safety carton pack or plywood box
Standards :IEC 60335-2-40:2022 and GB/T 4706.32-2024
Electrode Spark Gap :0.5-10mm adjustable
Transformer Voltage Range :0-20KV, resolution 1V
Discharge Time :0.3s ± 0.05s
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

1. Product Overview

The flame-retardant enclosure verification test chamber for A2L refrigerant is mainly used to test and verify the flame-retardant effect of flame-retardant enclosures in the event of A2L refrigerant leakage. The equipment complies with the requirements of IEC 60335-2-40:2022 and GB/T 4706.32-2024 standards. This test chamber simulates refrigerant leakage scenarios to test the flame-retardant performance of the enclosure after leakage.

2. Equipment Functions and Standards

This testing machine is designed according to international standards IEC 60335-2-40:2022 and GB/T 4706.32-2024, and is suitable for household appliances such as electric heat pumps, air conditioners, and dehumidifiers.

Its core functions include:

Simulating a refrigerant leak scenario, the flame-retardant effect of the flame-retardant enclosure was tested after the leak.

Verify whether the casing can effectively prevent the spread of flames after a leak.

Equipment composition

(1). One set of high-voltage spark generator

(2). One set of explosion-proof simulated environment chamber

(3). One control system

3 . Technical Parameters

(1). High-voltage spark generator

(2). Electrode Spark Gap: 0.5-10mm adjustable

(3). Transformer Voltage Range: 0-20KV, resolution 1V

(4). Discharge Time: 0.3s ± 0.05s

(5). Discharge Quantity: 30mA; Resolution: 0.01mA;

(6). Dry Bulb Humidity: 32℃ (can be set)

(7). Dew Point Temperature: 27℃ (can be set)

(8). Voltage Input: 220VAC

Inquiry Cart 0