KingPo Technology Development Limited

Manufacturer from China
Verified Supplier
9 Years
Home / Products / Flame Test Equipment /

A2L Refrigerant Hot Surface Ignition Tester with 304 Stainless Steel and 0-1000℃ Temperature Range for Flame Test Equipment

Contact Now
KingPo Technology Development Limited
Visit Website
City:hong kong
Province/State:hong kong
Country/Region:china
Contact Person:MsLynette Wong
Contact Now

A2L Refrigerant Hot Surface Ignition Tester with 304 Stainless Steel and 0-1000℃ Temperature Range for Flame Test Equipment

Ask Latest Price
Video Channel
Brand Name :Kingpo
Model Number :KP-FT3540
Certification :ISO 17025
Place of Origin :China
MOQ :1
Price :To be quoted
Payment Terms :T/T
Packaging Details :safety carton pack or plywood box
Contact Now

Add to Cart

Find Similar Videos
View Product Description

1. Product Overview

The A2L refrigerant hot surface ignition temperature tester determines the lowest temperature at which A2L refrigerant can be ignited by a high-temperature hot surface under specific conditions; this is known as the hot surface auto-ignition temperature. This data is crucial for assessing the potential fire risk when refrigerant leaks and encounters hot surfaces such as electrical components or overheated pipes.

2. Technical Parameters

2.1 Test Chamber: a pressure-resistant and high-temperature-resistant glass tube .

Glass Tube Material: Borosilicate .

Glass Tube Dimensions: Diameter 70mm±10mm, Height 230mm±10mm

2.2 Thermal Surface Assembly

Hot Surface Assembly: 304 stainless steel .

Thermal Surface Assembly Dimensions: Diameter 50mm ± 2mm, Thickness: 6mm

Surface Texture: conforms to ISO 1302

2.3 Sprinkler System

The sprinkler system consists of a liquid supply device, two valves, and pipelines that guide the spray .

The direct volume of the valve is 1.0 cm³ ± 0.2 cm³.

Spray Pipe Dimensions: Length 250mm ± 5mm, outer diameter ≤ 4mm, inner diameter: 1.6mm ± 0.1mm

2.4 Temperature Control System:

A high-precision PID controller and thermocouples (usually welded to the back of the hot plate ) are used to achieve precise control and measurement of the hot surface temperature.

Temperature Setting Range: 0-1000℃

Accuracy: ±1℃

Resolution: 0.1°C

2.5 Number of Tests: 0-999 (can be set)

Test Interval Time: 0-999 seconds can be set

2.6. Power Supply: 220V 50/60HZ 2000W

2.7 Equipment Dimensions: 1200*800*1500mm

2.8 Standards Compliance: IEC 60335-2-40 Appendix KK, UL 60335-2-40